Description
The Bosch MIC Alarm/Washer Interface unit consists of a weatherproof enclosure that houses surge-protected interface connections for alarm inputs, alarm outputs, washer relay, power connection, and serial data link to MIC7000 cameras. The unit is equipped with removal screw terminal blocks to simplify attachment of electrical connections to external cabling. Board mounted LED indicators provide status and diagnostic feedback.
Features
- Provides alarm and washer interface connections for MIC7000 cameras
- Impact-resistant polycarbonate enclosure rated to IP67 and NEMA 4X
- Watertight cable glands included
- Push button to activate/test connected washer pump
Parts included with this product:
- 1 x MIC Alarm/Washer Interface (MIC-ALM-WAS-24) enclosure with three (3) watertight M16 cable glands and one (1) M16 blanking plug installed
- 1 x Watertight M16 cable gland, uninstalled
- 4 x Pozidriv screws for lid
- 4 x Screw caps to cover the lid screws
- 1 x Installation manual
Datasheet
Tech Specs
Input voltage |
24 VAC ± 10%, 50/60 Hz |
Power consumption |
1.5 W |
Protection on RS-485 |
Peak current 10 A, peak power 300 W (8/20 μ) |
Protection on Alarm Inputs |
Peak current 17 A, peak power 300 W (8/20 μ) |
Protection on Alarm Outputs |
Peak current 2 A, peak power 300 W (8/20 μ) |
Protection on Relay Outputs |
Peak current 7.3 A, peak power 600 W (10/1000 μ) |
Protection on Power Input (Camera) |
Peak current 7.3 A, peak power 600 W (10/1000 μ) |
LEDs |
Red LED (ON indicates power on)Green LEDs (blinking indicates activation for each alarm input)Yellow LED (blinking indicates active communication between the MIC-ALM-WAS-24 and the MIC7000 camera) |
Communications Protocol |
Proprietary half-duplex RS-485, 57600 baud |
Power |
24 VAC |
Alarm Input |
4 normal dry contacts (selectable N.O./N.C.)2 monitored tamper alarm inputs, 2.2K ohm end-of-line termination |
Alarm Output |
3 open collector outputs, 32 VDC, 150 mA |
Relay Output |
1 dry contact relay, 24VAC/VDC, 5 A (for washer pump) |
Alarm/Data |
3-wire RS-485 (to external alarm/washer accessory unit) up to 100 m |
Ingress Protection Rating/ Standard |
IP67NEMA 4, 4X, 6, 12, 13 |
Operating Temperature |
-40 °C to +60 °C (-40 °F to +140 °F) |
Cold Start-up Temperature |
-40 °C (-40 °F) (Requires 60 minute warm-up prior to operation) |
Storage Temperature |
-40 °C to +70 °C (-40 °F to +158 °F) |
Humidity |
0-100% |
Dimensions(L x W x H) |
200 mm x 120 mm x 79 mm(7.9 in. x 4.7 in. x 3.1 in.) |